JH-GF1000 Dust Concentration Detector
The JH-GF1000 dust concentration detector uses a light-scattering principle and an imported high-precision processing core. It is designed to monitor dust concentration in workplaces and to detect coal dust and other dust in industrial and mining enterprises. It continuously detects and warns of exceeding the standard 24 hours a day to help prevent health risks for workers and reduce danger to life safety from explosion accidents caused by high dust concentrations.
Technical Parameters
Item |
Specification |
Detection Principle |
Light scattering principle |
Measurement Error |
±10% (reference value) |
Total Dust Concentration Range |
0.1 mg/m³ ~ 1000 mg/m³ |
Sampling Mode |
Suction type |
Signal Output |
4 ~ 20 mA, RS485 |
Operating Temperature |
-10°C ~ 55°C |
Operating Humidity |
≤ 95% RH (non-condensing) |
Operating Voltage |
18 V DC |
Operating Current |
≤ 100 mA |
Sampling Flow |
1.2 L/min |
Explosion-proof Type |
Intrinsic safety type |
Explosion-proof Mark |
Ex ib IIB T4 Gb / Ex ibD 21 T135°C |
Overall Dimension |
178 × 138 × 80 mm |
Features
On-site digital display shows dust concentration and provides synchronized sound and light alarms. Supports infrared remote control for settings;
Employs light scattering laser technology for sensitive and accurate measurement;
Uses a brushless motor for stable, reliable operation and a long service life;
The product has obtained dual explosion-proof certification and is equipped with an explosion-proof sound and light alarm;
4–20 mA and RS485 (Modbus RTU) signal output.
Application